Here you will find the Agency listing information relating to Resideo security products. This page is constructed around the following sections. Please select which section you require.

UL/CUL Listings

How to acquire listing cards

The following is a brief description of how to use UL’s website to acquire Listing cards.

1. Go to
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm

2. Type a model in the box next to Keyword

****You can also type a company name, part number, file number, etc.****

NOTE: Some problems you may encounter are:

a. Dashes and spaces may be an issue. [i.e. VISTA-128FB or VISTA 128FB]

b. Partial descriptions sometimes exist. [i.e. VISTA-128FB may not give you all Listed categories for that product. If you type 128FB also, you will get one additional that didn’t appear on the original search of the Vista-128FB - There are only a few of these that act in this manner].

3. The results of your search will bring you to another screen with selections in blue, such as UOJZ.S789 [which represent: Category Control Number. File Number].

4. Select one of these blue descriptors and you will go directly to the Listing cards for that category.

NOTE: This selected document will include every UL Listing in that product category for that corresponding company.

5. Now you may view/print these pages.

ADDITIONAL NOTES:

FOR US LISTINGS –

UOJZ – Control Units Systems which means that you will be viewing the COMMERCIAL FIRE Listings;

FOR CANADIAN LISTINGS

UOJZ7or 8 – Control Units Systems which means that you will be viewing the COMMERCIAL FIRE Listings.

Definitions of Terms
Terms - Meaning
The word "Burglar" Means "Commercial Burg"
The word "Burglary" Means "Household Burg"
The word "Accessory" Component suitable for use with control panels that support it
The word "Sub-Assembly" Control Panel PCB suitable for use in one or more enclosures
Samples of Basic Label Wordings - Meaning -
Signal System Control Unit Commercial Fire Alarm Panel
Signal System Control Unit Sub-Assembly Commercial Fire Alarm Panel pcb suitable for use in a specific enclosure
Signaling Device Accessory for use with specific Commercial Fire Alarm Panels
Household Fire Warning System Control Unit Household Fire Alarm Panel
Household Fire Warning System Control Unit Accessory Accessory for use with specific Household Fire Alarm Panels
Burglar Alarm System Control Unit Commercial Burg Alarm Panel
Burglar Alarm System Control Unit Sub-Assembly Commercial Burg Alarm Panel pcb suitable for use in a specific enclosure
Household Burglary Warning System Control Unit Household Burg Alarm Panel
Household Burglary Warning System Control Unit Accessory Accessory for use with specific Household Burg Alarm Panels
ACTUAL LABEL TEXT - Meaning
Signal System Control Unit Commercial Fire Alarm Panel
Also Suitable For Use As A Also Suitable For Use As A
Burglar Alarm System Control Unit Commercial Burg Alarm Pane
Signal System Control Unit Sub-Assembly Commercial Fire Alarm Panel pcb to be used in a specific enclosure
Also Suitable For Use As A Also Suitable For Use As A
Burglar Alarm System Control UnitSub-Assembly Commercial Burg Alarm Panel pcb to be used in a specific enclosure
Signaling Device Accessory for use with specific Commercial Fire Alarm Panels
Also Suitable For Use As A Also Suitable For Use As A
Household Fire and Burglary WarningSystem Control Unit Accessory Accessory for use with specific Household Fire/Burg Alarm Panels
And A Burglar Alarm System Accessory Accessory for use with specific Commercial Burg Alarm Panels
Household Fire and Burglary WarningSystem Control Unit Household Fire/Burg Alarm Panel
Household Fire and Burglary WarningSystem Control Unit Accessory Accessory for use with specific Household Fire/Burg Alarm Panels
Household Fire and Burglary WarningSystem Control Unit Enclosure Household Fire/Burg Alarm Panel Enclosure
**These are also suitable for use with pcb Sub-Assemblies**
Household Fire and Burglary WarningSystem Control Unit Assembly Household Fire/Burg Alarm Panel pcb suitable for use in a specific enclosure
Also Suitable For Use As A Also Suitable For Use As A
Burglar Alarm Unit Sub-Assembly Commercial Burg Alarm Panel pcb suitable for use in a specific enclosure
Household Fire and Burglary WarningSystem Control Unit Accessory Accessory for use with specific Household Fire/Burg Alarm Panels
Also Suitable For Use As A Also Suitable For Use As A
Burglar Alarm System Accessory Accessory for use with specific Commercial Burg Alarm Panels
Definitions of Category Control Numbers

Definitions of Category Control Numbers which are found at the top of the UL Listing cards

Category Control Number (CCN)

ULcUL

Category Name
Actual Meaning
Applicable UL Standards
Applicable ULC or CSA Standards Used For Canadian Certification
ALVY
ALVY7
Access Control System Units
Access Control Unit
UL294
Covered CSA 222 -205, M1983.
AMCX
AMCX7
Central Station Alarm Units
Commercial Burg Alarm
UL1610 **
CAN/ULC-S304-M88, "Central and Monitoring Station Burglar Alarm Units" and UL 1635, "Digital Alarm Communicator System Units."
AMQV
AMQV7
Connectors and Switches
Contacts
UL634
ULC C634 "Connectors and Switches for Use With Burglar alarm Systems".
ANET
ANET7
Holdup Alarm Units
Commercial Burg Alarm
UL636 **
CAN/ULC-S303-1991 (R1999), Local Burglar Alarm Systems and Units and CAN/ULC-S304-1988, Central and Monitoring Station Burglar Alarm Units.
ANSR
ANSR7
Intrusion Detection Unit
Motion Detectors & Glass Breaks
UL639 **
ULC-S306, "Intrusion Detection Units".
AOTX
AOTX7
Local Alarm Units
Commercial Burg Alarm
UL464 for Audibility requirements UL609 for constructional requirements **
CAN/ULC-S303, "Local Burglar Alarm Units and Systems" and CAN/ULC-S525, "Audible Signal Appliances.
APAW
APAW7
Police Station Alarm Unit
Commercial Burg Alarm
UL464 for Audibility requirements UL365 for constructional requirements **
CAN/ULC -S303-M91, "Local Burglar Alarm Units and Systems," CAN/ULC-S304-M88, "Central and Monitoring Burglar Alarm Units" and CAN/ULC-S525, "Audible Signal Appliances."
APOU
APOU7
Proprietary Alarm Units
Commercial Burg Alarm
UL1076 **
UL 1076, "Proprietary Burglar Alarm Units and Systems."
DRQH
DRQH7
Closed Circuit Television Equipment
CCTV Equipment
UL2044
CAN/CSA-C22.2 No. 1, "Audio, Video and Similar Electronic Equipment".
MULQ
MULQ7
Home Health Care Signaling Equipment
Suitable for Home Health Care Use
UL1637
No equivalent Canadian Standard.
NBSX
NBSX7
Household Burglar Alarm System Units
Residential Burg Alarm
UL1023 **
UL1023 "Household Burglar Alarm System Units".
NWGQ
NWGQ7
Information Technology Equipment Including Electrical Business Equipment
IT Equipment and Telco-Connected Equipment
UL1950
CAN/CSA-C22.2 No. 950 and CAN/CSA-C22.2 No. 60950, "Safety of Information Technology Equipment."
UOJZ
UOJZ7
Control Units, System
Commercial Fire Alarm
UL864 **
CAN/ULC-527, "Control Units for Fire Alarm Systems".
UOXX
UOXX7
Control Unit Accessories, System
Commercial Fire Alarm
UL864 **
CAN/ULC-S527-M87, "Control Units for Fire Alarm Systems".
UROX
UROX7
Smoke - Automatic Fire Detectors
Residential & Commercial Smokes - No sounder required
UL268
CAN/ULC 529 "Smoke Detectors for Fire Alarm Systems"
UTGT
UTGT7
Single and Multiple Station Smoke Detectors
Residential Smokes - Sounder & Temporal Alarm required
UL217
CAN/ULC-S531, "Smoke Alarms".
UTOU
UTOU7
Control Unit and Accessories - Household System Type
Residential Fire Alarm
UL985 **
CAN/ULC S545, "Residential Fire Warning System Control Units".
** Note: Any equipment with a digital communicator has been evaluated to UL1635.

ULC Listing Cards

1. The following is a brief description of how to use UL’s website to acquire Listing cards.

http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm

2. Type a model in the box next to Keyword

****You can also type a company name, part number, file number, etc.****

NOTE: Some problems you may encounter are:

a. Dashes and spaces may be an issue. [i.e. Vista-128FB or Vista 128FB]

b. Partial descriptions sometimes exist. [i.e. Vista-128FB may not give you all Listed categories for that product. If you type 128FB also, you will get one additional that didn’t appear on the original search of the Vista-128FB - There are only a few of these that act in this manner].

3. The results of your search will bring you to another screen with selections in blue, such as UOJZ.S789 [which represent: Category Control Number. File Number].

4. Select one of these blue descriptors and you will go directly to the Listing cards for that category.

NOTE: This selected document will include every UL Listing in that product category for that corresponding company.

5. Now you may view/print these pages.

ULC Website

CSFM Certificates

Step 1: Get the CSFM Certification number from the correlation sheet with corresponding Resideo part numbers.

 

How to find a CSFM Certification number:

GO TO CORRELATION SHEET and get CSFM Certification number

EXAMPLE: A VISTA-128FB Certification Number is 7165-1645:0123, where,

7165 is the Category Number
1645 is the Assigned Company Code
0123 is the Listing Index Number [sequential].

NOTE 1: The 1645 portion of the number is VERY Important.

Step 2: Once you’ve obtained the CSFM certificate number, go to Instructions on how to use CSFM’s search, below.

 

Instructions on how to use CSFM's search:

Step 1: Go to https://osfm.fire.ca.gov/

Step 2: Select “Resideo Security” for company name

Step 3: Click on SEARCH

Step 4: Select “desired certificate” for Listing

 

To Search for parts that are not found in the correlation sheet:

Step 1: Select the part’s category from the Sort by Categories option. (company and Listing options remain at “All Listings”)

Step 2: Click on SEARCH

Step 3: To find the desired part, click “Ctrl F” [FIND FEATURE] and enter the part number.

EXAMPLE: For 5193SD select 7272-Smoke Detector-Photoelectric from category and do search.

Enter 5193SD in the find feature window and click find. It will take you to certificate number 7272-1653:0210

Government (NIST)

For Advanced Encryption - FIPS 197 approved.

Latest version -
Cert # 979 for our Internet Devices is described on the NIST site as:

Alarmnet-i communications uses AES in CBC mode with 256-bit key. The module is embedded in the entire family of Alarmnet-i communicators including (but not limited to) 7845i-GSM, 7845i-GSMCN, 7845i-GSMG, iGSMCF, and 7847i. Alarmnet-i's AES software module is written in C and encapsulates encryption/decryption services for Alarmnet-i

Previous version -
Cert # 127 for our Internet Devices is described on the NIST site as:

The AlarmNet-i is used in our 7810ir, 7810ir-ent, 7845i, 7845i-ent and 8132 devices. The software module handles the encryption function for each product and is an encapsulated C++ module. 

For Triple DES Encryption - FIPS 46-3 approved.

Cert. # 195 for the AC Communicator model is described on the NIST site as:

The AC Communicator Module (P/N 472491D3) is used to encrypt and transmit security system data over public telephone line, RS232 and DVAC to proprietary central station automation equipment.

Get information about the GOVHS-KT1 product kit for UL 2050 applications. If you have questions concerning UL 2050,please contact our support.

UL 2075 5800CO UL 2075 Compatibility

Below is a list of Resideo products that meet the UL 2075 System Listing when used with the 5800CO. Please be sure to check this site frequently as we continue to add products.

Product  Revision
Controls
LYNXR-I Series
17 or higher
VISTA-21iP
1.0 or higher
VISTA-21iPSIA
1.0 or higher
VISTA-20P
7.0 or higher
VISTA-15P
6.1 or higher
VISTA-10P
4.0 or higher
VISTA-20PSIA
7.0 or higher
VISTA-15PSIA
6.1 or higher
VISTA-10PSIA
4.0 or higher
FA168CPS
7.0 or higher
FA148CP
6.1 or higher
FA130CP
4.0 or higher
FA168CPSSIA
7.0 or higher
FA148CPSSIA
6.1 or higher
FA130CPSSIA
4.0 or higher
Keypads
6160
V101 or higher
6160CR
V101 or higher
6150
V102 or higher 
6148
V102 or higher
FA570KP
V101 or higher
FA220KP
V102 or higher
back-to-top